Hot Products
Tabletop Low Speed Sanguinis Separatio Refrigerated Centrifuge Large Capcity Medical
| Applications: | Hospitalia, Veterinaria Clinics, Cibus Labs, Universitates & Collegia, Labs Pharmaceutical, Cell Culture Labs |
| Max.Speed | 6000rpm |
| Max.RCF | 4752xg |
| Max.Capacity | Situla oscillans 4*750ml |
| Imperium temperatus range | -20 ℃ ~ ℃ 40 |
| matched Rotors | Fixed angle rotors&swing out rotors |
| Display | LCD |
| Model Number: | TDL-5M |
| Certification: | CE, ISO13485, ISO9001, SFDA |
| Suspendisse | 1 annus warantum pro tota machina, 3 annorum warantum pro compressore et 5 annis warantizatio motoris. Free partes replacement et naves intra warantum. |
- Description
- Video
- Technical Specifications
- Rotors and Accessories
- competitive Italiae Commodum Collegit
Low speed refrigerated centrifuge TDL-5M is typically used in scientific research and medical laboratories to separate substances of different densities in a sample. The refrigeration feature allows for temperature control during the separation process, which is important for maintaining the integrity of certain samples.
Design
● Habitatio metallica, operculum metallicum, et fabricae fabricae chalybeis immaculatae sunt autoclave-biles et renitentes detergentes et disinfection liquidorum.
● Observationes fenestrae in operculo ad celeritatem calibrationis et sonitus mensurae.
Microprocessor imperium cum frequentia conversionem AC motricium coegi
● LCD parametros velocitatis, Timer, RCF, Rotors, Programma (Memoria), Acceleratio & Deceleratio informationes ac Erroris notas exhibe.
Duplex strata obsignatio operculo fabricato ad fabricam fabricam et instrumentum ad diuturnitatem boni obsignandi.

user benignos
● CFC ratio refrigerationis liberae, pluma refrigerationis Pre-coctae, praecisa temperaturae moderatio usque ad - 20°C.
● Programmabile et reponendum, usque ad XXX programmata reponit ac directum user accessum praebet cum uno keystroke nisi. Parametrum repositum: iunctura manet in memoria etiam post centrifugationem emissa est.
Acceleratio rates praebet et 10 aggerem bracchium, ut sedimentationem secundariam efficaciter vitet, cum effectu centrifugationis meliore.
Lorem operculo-densis et tenens in rotor run
● Rotors commutabiles facile, speciales rotor iunctio, qui facilem faciunt rotor onerare et exonerare.
● Lorem sollicitudin ante indicatis erroris code et terrorem in screen.
technologiam mutam patentem. Vox minor quam 58 decibel in summa celeritate gyratorii.
Lorem rpm/rcf conversionem
● Rotor identitatis automaticae, identificatio rotor coded impedit rotorem super velocitate.

salutem
Produci secundum normas securitatis internationales (eg IEC 61010)
● Salus operculi electricae interlock, ianua aperire non potest cum rotor currit et apparatus non currit cum operculo aperto et in codice error apparet.
● Subitis operculo-cincinno emissio cum potentia deficiendi (utilissima in inopinato potentiae interruptione).
● Gas cardo operculi stilla munimenti.
● Praesidia salutis fiunt pro cursu, super calefactione (motor, cubiculo), inaequalitate etc. ut homo salutem machinam conservet.

| Celeritate range (rpm) | 0-6000rpm vocabulary | Tempus range | 1-99 minuta adaptabilia |
| Max Capacity(ml) | 4* 750ml | celeritate accuracy | ±10r/min |
| RCF range (xg) | 0-4752xg vocabulary | ACC/DEC | 1-10 rates |
| Imperium temperatus range | -20 ℃ ~ ℃ 40 | Accuracy temperatus imperium | ± 1 ℃ |
| Strepitu (dBA) | 58dB(A) | Net pondus (sine rotor) | 100KGS |
| potentia copia | AC220V,50HZ,10A, 1300W | Ratio (mm) | 735x690x400mm (LxWxH) |
| No. | Item | Max. facultatem | Max.speed | Max.RCF | Nota |
| NO.1 | Angulus rotor | 12x15/10/5ml | 6000r / min | 4588xg | PP/PC tube |
| nibh | 12x2ml | PP/PC tube | |||
| NO.2 | Rotor adductius | ferro frame rotor | 5000r / min | 4752xg | PP/PC tube |
| frame adductius | 4x100ml | PP/PC tube | |||
| frame adductius | 4x50ml | PP/PC tube | |||
| nibh | 4x15/10ml | PP/PC tube | |||
| NO.3 | Rotor adductius | ferro frame rotor | 4000r / min | 3041xg | PP/PC tube |
| frame adductius | 4x2x100ml | PP/PC tube | |||
| frame adductius | 4x2x50ml | PP/PC tube | |||
| nibh | 4x2x15/10ml | PP/PC tube | |||
| frame adductius | 4x8x15/10/5ml | PP/PC tube | |||
| eculeo | 4×12×5/2ml | PP/PC tube | |||
NO.4
|
Swing bucket | 4x18x5/2ml | 4000r / min | 2773xg | Vacuum sanguinis collectionem tube |
N0.5
|
Situla adductius | II x 4ml | 4000r / min | 3354xg | Quadratum poculum |
| nibh | 4×25×5/2ml | Vacuum sanguinis collectionem tube | |||
| nibh | 4×12×15/10ml | PP/PC tube | |||
| nibh | 4×5×50ml | PP/PC tube | |||
| nibh | 4×4×100ml | PP/PC tube | |||
NO.6
|
Situla adductius | II x 4ml | 4000r / min | 3354xg | Round cup |
| nibh | 4×17×5/2ml | PP/PC tube | |||
| nibh | 4×8×15/10ml | PP/PC tube | |||
| nibh | 4×3×50ml | PP/PC tube | |||
| nibh | II x 4ml | PP/PC tube | |||
NO.7
|
Situla adductius | II x 4ml | 4000r / min | 3400xg | Round cup |
| nibh | 4×26×5/2ml | PP/PC tube | |||
| nibh | 4×13×15/10ml | PP/PC tube | |||
| nibh | 4×5×50ml | PP/PC tube | |||
| nibh | 4×3×100ml | PP/PC tube | |||
NO.8
|
Microplate rotor | 2×2×96hole | 4200r / min | 2860xg | Quadratum poculum |
| nibh | 2×32×1.5ml | PP/PC tube | |||
![]() | |||||
1.Professio centrifugium opificem, pretium competitive.
2.ISO9001, ISO13485, CE, SFDA Certificatione, omnes machinae qualitatem strictam experiuntur et bonae sarcinae ante translationem subeunt.
3. Longum tempus technicum subsidium ac professionalis servitii in omni stadio producti venditionis, partus et operationis. Nostri quadrigis maxime idonei et periti servitii praebent te singulari gradu subsidii pro tua emptione pro tota vita sua.
4. Etiam solutiones nativus pro clientium specialibus requisitis offerre possumus.
5. Potestas cum efficiente machinarum iunctione per annos experientiae in suis propriis agris adiuta, societas unumquemque productum efficit, quod unitas fabricandi relinquit ad omnia usque ad finem.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ

















