Hot Products
Magnae capacitatis Centrifuge cum UV Lucerna Biosafety pro Laboratorio Et Medical
| Applications: | Industriales Labs, Hospitales, Veterinaria Clinics, Cibus Labs, Universitates & Collegia, Labs Pharmaceutical, Cell Cultura Labs |
| Max.Speed | 6000rpm |
| Max.RCF | 4752xg |
| Max.Capacity | 4* 1000ml |
| matched Rotors | Fixum angulum rotor, situla adductius |
| Display | LCD |
| Model Number: | DL-5M |
| Certification: | CE, ISO13485, ISO9001, SFDA |
| Suspendisse | 1 annus warantum pro tota machina, 3 annorum warantum pro compressore et 5 annis warantizatio motoris. Free partes replacement et naves intra warantum. |
- Description
- Video
- Technical Specifications
- Rotors and Accessories
- competitive Italiae Commodum Collegit
Centrifuga refrigerata stans in solo DL-5M, quae rotorem fixum magnae capacitatis, exempli gratia 4*1000ml, et etiam rotorem oscillantem tractare potest, late in campis stationum sanguinis, officinorum pharmaceuticarum, biochemiae, productorum biologicorum, etc. adhibita est. Instrumentum ideale est ad separationem sanguinis, praecipitationem proteinorum, et collectionem cellularum, et certificationibus securitatis CE, ISO9001, et qualitatis 13485 congruit.
Design
● Habitatio metallica, operculum metallicum, et fabricae fabricae chalybeis immaculatae sunt autoclave-biles et renitentes detergentes et disinfection liquidorum.
● Observationes fenestrae in operculo ad celeritatem calibrationis et sonitus mensurae.
Microprocessor imperium cum frequentia conversionem AC motricium coegi
● LCD parametros velocitatis, Timer, RCF, Rotors, Programma (Memoria), Acceleratio & Deceleratio informationes ac Erroris notas exhibe.
Duplex strata obsignatio operculo fabricato ad fabricam fabricam et instrumentum ad diuturnitatem boni obsignandi.
● Bio-safety: caput gas- strictum revolvens quod in caliditas caliditatis centrifugualis potest sterilis esse, cum sterilizationis functionis ultravioletae cavitas ingreditur, sterilizationem status post conversionem in machinam ingreditur.
● Multi-strata designant adaptatorem, operabilem pro 100mm et 75mm tubo, operculum automatice tolle, efficientiam meliorem.
● Bio-safety: caput gas- strictum rotatum quod in caliditate caliditatis centrifugae sterilis fieri potest, cum sterilizationis functione ultraviolet, intra statum sterilitatis post conversionem in.

user benignos
● Programmabile et reponendum, usque ad XXX programmata reponit ac directum user accessum praebet cum uno keystroke nisi. Parametrum repositum: iunctura manet in memoria etiam post centrifugationem emissa est.
Acceleratio rates praebet et 10 aggerem bracchium, ut sedimentationem secundariam efficaciter vitet, cum effectu centrifugationis meliore.
Lorem operculo-densis et tenens in rotor run
● Rotors commutabiles facile, speciales rotor iunctio, qui facilem faciunt rotor onerare et exonerare.
● Lorem sollicitudin ante indicatis erroris code et terrorem in screen.
technologiam mutam patentem. Vox minor quam 55 decibel in summa celeritate gyratorii.
Lorem rpm/rcf conversionem
● Rotor identitatis automaticae, identificatio rotor coded impedit rotorem super velocitate.
● CFC ratio refrigerationis liberae, pluma refrigerationis Pre-coctae, praecisa temperaturae moderatio usque ad - 20°C.

salutem
Produci secundum normas securitatis internationales (eg IEC 61010)
● Salus operculi electricae interlock, ianua aperire non potest cum rotor currit et apparatus non currit cum operculo aperto et in codice error apparet.
● Subitis operculo-cincinno emissio cum potentia deficiendi (utilissima in inopinato potentiae interruptione).
● Gas cardo operculi stilla munimenti.
● Praesidia salutis fiunt pro cursu, super calefactione (motor, cubiculo), inaequalitate etc. ut homo salutem machinam conservet.

| Celeritate range (rpm) | 0-6000rpm vocabulary | Tempus range | 1-99minutes Novifacta |
| Max Capacity(ml) | 4* 1000ml | celeritate accuracy | ±10r/min |
| RCF range (xg) | 0-4752xg vocabulary | ACC/DEC | 1-10 rates |
| Imperium temperatus range | -20 ℃ ~ ℃ 40 | Accuracy temperatus imperium | ± 1 ℃ |
| Strepitu (dBA) | 58dB(A) | Net pondus (sine rotor) | 200KGS |
| potentia copia | AC220V,50HZ,10A, 1800W | Ratio (mm) | 790x670x900mm (LxWxH) |
| No. | Item | Max. facultatem | Max.speed | Max.RCF | Nota |
NO.1
| Angulus rotor | 12 x 15/10/5ml | 6000r / min | 4588xg | PP/PC tube |
| nibh | 12x2ml | PP/PC tube | |||
NO.2 | Rotor adductius | Ferro frame rotor | 5000r / min | 4752xg | PP/PC tube |
| frame adductius | 4x100ml | PP/PC tube | |||
| frame adductius | 4x50ml | PP/PC tube | |||
| nibh | 4x10/15ml | PP/PC tube | |||
N0.3 | Rotor adductius | Ferro frame rotor | 4000r / min | 3041xg | PP/PC tube |
| frame adductius | 4×2×100ml | PP/PC tube | |||
| frame adductius | 4×2×50ml | PP/PC tube | |||
| frame adductius | 4×8×15/10/5ml | PP/PC tube | |||
| nibh | 4×2×10/15ml | PP/PC tube | |||
| eculeo | 4×12×5/2ml | PP/PC tube | |||
NO.4 | Situla adductius | 4 × 18×5/2ml | 4000r / min | 2773xg | Vacuum sanguinis collectionem tube |
NO.5 | Situla adductius | II x 4ml | 4000r / min | 3354xg | Calix rectangulus pendulus |
| Decapping nibh | 4×25×5/2ml | PP/PC tube | |||
| nibh | 4×12×15/10ml | PP/PC tube | |||
| nibh | 4×5×50ml | PP/PC tube | |||
| nibh | 4×4×100ml | PP/PC tube | |||
NO.6 | Situla adductius | II x 6ml | 4000r / min | 3400xg | Calix rectangulus pendulus cum tegumento ventorum |
| Decapping nibh | 6×25×5/2ml | PP/PC tube | |||
| nibh | 6×12×15/10ml | PP/PC tube | |||
| nibh | 6×5×50ml | PP/PC tube | |||
| nibh | 6×4×100ml | PP/PC tube | |||
| NO.7 | Situla adductius | II x 4ml | 4000r / min | 3354xg | circum tentorium calicem, |
| nibh | 4×17×5/2ml | PP/PC tube | |||
| nibh | 4×8×15/10ml | PP/PC tube | |||
| nibh | 4×3×50ml | PP/PC tube | |||
| nibh | II x 4ml | PP/PC tube | |||
| NO.8 | Situla adductius | II x 6ml | 4000r / min | 3400xg | circum tentorium poculum cum tegumento venti |
| nibh | 6×17×5/2ml | PP/PC tube | |||
| nibh | 6×8×15/10ml | PP/PC tube | |||
| nibh | 6×3×50ml | PP/PC tube | |||
| nibh | II x 6ml | PP/PC tube | |||
| NO.9 | Situla adductius | II x 4ml | 4000r / min | 3443xg | Calix rectangulus suspensus cum tegumento vento |
| Decapping nibh | 4×30×5/2ml | PP/PC tube | |||
| nibh | 4×12×15/10ml | PP/PC tube | |||
| nibh | 4×6×50ml | PP/PC tube | |||
| nibh | 4 × 4×100ml | PP/PC tube | |||
| NO.10 | Situla adductius | II x 4ml | 4000r / min | 3443xg | Calix rotundus pendulus |
| nibh | 4×26×5/2ml | PP/PC tube | |||
| nibh | 4×13×15/10ml | PP/PC tube | |||
| nibh | 4×5×50ml | PP/PC tube | |||
| nibh | 4 × 3×100ml | PP/PC tube | |||
| NO.11 | Situla adductius | II x 4ml | 4000r / min | 3578xg | Calix rhomboideus pendulus cum tegumento ventorum |
| Decapping nibh | 4×42×5/2ml | PP/PC tube | |||
| nibh | 4×18×15/10ml | PP/PC tube | |||
| nibh | 4×7×50ml | PP/PC tube | |||
| nibh | 4 × 4×100ml | PP/PC tube | |||
| NO.12 | Microplate rotor | 4×2×96 foramen | 4200r / min | 3284xg | Lamina foraminis profundi 4×2×96 Lamina foraminis superficialis 4×4×96 |
| nibh | 4 × 32×1.5ml | ||||
![]() | |||||
1.Professio centrifugium opificem, pretium competitive.
2.ISO9001, ISO13485, CE, SFDA Certificatione, omnes machinae qualitatem strictam experiuntur et bonae sarcinae ante translationem subeunt.
3. Longum tempus technicum subsidium ac professionalis servitii in omni stadio producti venditionis, partus et operationis. Nostri quadrigis maxime idonei et periti servitii praebent te singulari gradu subsidii pro tua emptione pro tota vita sua.
4. Etiam solutiones nativus pro clientium specialibus requisitis offerre possumus.
5. Potestas cum efficiente machinarum iunctione per annos experientiae in suis propriis agris adiuta, societas unumquemque productum efficit, quod unitas fabricandi relinquit ad omnia usque ad finem.