Hot Products
Fuscus Centrifuge 6000Rpm pro 2Ml /5Ml/10Ml Sanguis Bd Vacutainer Tube Cum Biosafety Cover
| Applications: | Industriales Labs, Hospitales, Veterinaria Clinics, Cibus Labs, Universitates & Collegia, Labs Pharmaceutical, Cell Cultura Labs |
| Max.Speed | 6000rpm |
| Maximilianus. RCF | 4588xg |
| Max.Capacity | 4* 1000ml |
| matched Rotors | Rotor anguli fixi, situla oscillans cum operculo camerae venti, situla aeris permeabilis cum operculo venti |
| Display | LCD |
| Model Number: | MK650 |
| Certification: | CE, ISO13485, ISO9001, SFDA |
| Suspendisse | 1 annus warantum pro tota machina, 3 annorum warantum pro compressore et 5 annis warantizatio motoris. Free partes replacement et naves intra warantum. |
- Description
- Video
- Technical Specifications
- Rotors and Accessories
- competitive Italiae Commodum Collegit
Centrifuga stans MK650, quae rotorem fixum magnae capacitatis, exempli gratia 4*1000ml, et etiam rotorem oscillantem tractare potest, late in campis stationum sanguinis, officinarum pharmaceuticarum, biochemiae, productorum biologicorum, etc. adhibita est. Instrumentum ideale est ad separationem sanguinis, praecipitationem proteinorum, et collectionem cellularum, et certificationibus securitatis CE, ISO9001, et qualitatis 13485 congruit.
Design
● Habitatio metallica, operculum metallicum, et fabricae fabricae chalybeis immaculatae sunt autoclave-biles et renitentes detergentes et disinfection liquidorum.
● Observationes fenestrae in operculo ad celeritatem calibrationis et sonitus mensurae.
Microprocessor imperium cum frequentia conversionem AC motricium coegi
● LCD parametros velocitatis, Timer, RCF, Rotors, Programma (Memoria), Acceleratio & Deceleratio informationes ac Erroris notas exhibe.
Duplex strata obsignatio operculo fabricato ad fabricam fabricam et instrumentum ad diuturnitatem boni obsignandi.
● Bio-safety: caput gas- strictum revolvens quod in caliditas caliditatis centrifugualis potest sterilis esse, cum sterilizationis functionis ultravioletae cavitas ingreditur, sterilizationem status post conversionem in machinam ingreditur.
● Multi-strata designant adaptatorem, operabilem pro 100mm et 75mm tubo, operculum automatice tolle, efficientiam meliorem.
● Securitas biologica: caput rotans gasibus impervium quod alta temperatura sterilizari potest, cavitas centrifuga cum radiis ultraviolaceae.

user benignos
● Programmabile et reponendum, usque ad XXX programmata reponit ac directum user accessum praebet cum uno keystroke nisi. Parametrum repositum: iunctura manet in memoria etiam post centrifugationem emissa est.
Acceleratio rates praebet et 10 aggerem bracchium, ut sedimentationem secundariam efficaciter vitet, cum effectu centrifugationis meliore.
Lorem operculo-densis et tenens in rotor run
● Rotors commutabiles facile, speciales rotor iunctio, qui facilem faciunt rotor onerare et exonerare.
● Lorem sollicitudin ante indicatis erroris code et terrorem in screen.
technologiam mutam patentem. Vox minor quam 55 decibel in summa celeritate gyratorii.
Lorem rpm/rcf conversionem
● Systema automaticum identificationis rotoris, identificatio rotoris codificata impedit rotorem ne celeritate nimia augeatur. vel post probationem PCR, quod effectus probationis magnopere emendat.

salutem
Produci secundum normas securitatis internationales (eg IEC 61010)
● Salus operculi electricae interlock, ianua aperire non potest cum rotor currit et apparatus non currit cum operculo aperto et in codice error apparet.
● Subitis operculo-cincinno emissio cum potentia deficiendi (utilissima in inopinato potentiae interruptione).
● Gas cardo operculi stilla munimenti.
● Praesidia salutis fiunt pro cursu, super calefactione (motor, cubiculo), inaequalitate etc. ut homo salutem machinam conservet.

| Celeritate range (rpm) | 0-6000rpm vocabulary | Tempus range | 1s-99 minuta adaptabile |
| Max Capacity(ml) | 4* 1000ml | celeritate accuracy | ±10r/min |
| RCF range (xg) | 0-4588xg vocabulary | ACC/DEC | 1-10 rates |
| Strepitu (dBA) | 55dB(A) | Net pondus (sine rotor) | 135KGS |
| potentia copia | AC220V,50HZ,10A, 1200W | Ratio (mm) | 775x620x900mm (LxWxH) |
| No. | Item | Max. facultatem | Max.speed | Max.RCF | Nota |
|
NO.1
|
Angulus rotor | 12x15/10/5ml | 6000r / min | 4588xg | PP/PC tube |
| nibh | 12x2ml | PP/PC tube | |||
|
NO.2
|
Situla adductius | 4x600ml | 4000r / min | 3354xg | Quadratum calicem cum vento operimentum |
| nibh | 4x25x5/2ml | Sanguis collectionis tube | |||
| nibh | 4x12x15/10ml | PP/PC tube | |||
| nibh | 4x5x50ml | PP/PC tube | |||
| nibh | 4x4x100ml | PP/PC tube | |||
|
N0.3
|
Situla adductius | II x 4ml | 4000r / min | 3443xg | Poculum quadratum cum tegumento ventorum |
| nibh | 4×30×5/2ml | Sanguis collectionis tube | |||
| nibh | 4×12×15/10ml | PP/PC tube | |||
| nibh | 4×6×50ml | PP/PC tube | |||
| nibh | 4×4×100ml | PP/PC tube | |||
|
NO.4
|
Situla adductius | II x 6ml | 4000r / min | 3400xg | Poculum quadratum cum tegumento ventorum |
| nibh | 6×25×5/2ml | Sanguis collectionis tube | |||
| nibh | 6×12×15/10ml | PP/PC tube | |||
| nibh | 6×5×50ml | PP/PC tube | |||
| nibh | 6×4×100ml | PP/PC tube | |||
|
NO.5
|
Situla adductius | II x 4ml | 4000r / min | 3578xg | Calix ovalis cum tegumento ventorum |
| nibh | 4×42×5/2ml | Sanguis collectionis tube | |||
| nibh | 4×18×15/10ml | PP/PC tube | |||
| nibh | 4×7×50ml | PP/PC tube | |||
| nibh | 4×4×100ml | PP/PC tube | |||
|
NO.6
|
Situla adductius | II x 4ml | 4000r / min | 3443xg | Calix hermeticae aeris cum operculo venti |
| nibh | 4×28×5/2ml | Sanguis collectionis tube | |||
| nibh | 4×9×15/10ml | PP/PC tube | |||
| nibh | 4×5×50ml | PP/PC tube | |||
| nibh | 4×3×100ml | PP/PC tube | |||
![]() | |||||
1.Professio centrifugium opificem, pretium competitive.
2.ISO9001, ISO13485, CE, SFDA Certificatione, omnes machinae qualitatem strictam experiuntur et bonae sarcinae ante translationem subeunt.
3. Longum tempus technicum subsidium ac professionalis servitii in omni stadio producti venditionis, partus et operationis. Nostri quadrigis maxime idonei et periti servitii praebent te singulari gradu subsidii pro tua emptione pro tota vita sua.
4. Etiam solutiones nativus pro clientium specialibus requisitis offerre possumus.
5. Potestas cum efficiente machinarum iunctione per annos experientiae in suis propriis agris adiuta, societas unumquemque productum efficit, quod unitas fabricandi relinquit ad omnia usque ad finem.