All Categories
Laboratorium Centrifuge

Laboratorium Centrifuge

Home> Producta- TJNE > machinarum ad atomos accelerandos > Laboratorium Centrifuge

Foedus Casio Refrigerated Centrifuge cum Low Sonitus

Applications:Hospitalia, Veterinaria Clinics, Cibus Labs, Universitates & Collegia, Labs Pharmaceutical, Cell Culture Labs
Max.Speed21000rpm cum angulo fixo rotor 12x1.5/2.2ml
Max.RCF31061xg
Max.CapacityIV * 4ml fixum angulus rotor
Imperium temperatus range-20 ℃ ~ ℃ 40
matched RotorsFixum angulum rotors
DisplayLCD
Model Number:TGL-20M
Certification:CE, ISO13485, ISO9001, SFDA
Suspendisse1 annus warantum pro tota machina, 3 annorum warantum pro compressore et 5 annis warantizatio motoris. Free partes replacement et naves intra warantum.
  • Description
  • Video
  • Technical Specifications
  • Rotors and Accessories
  • competitive Italiae Commodum Collegit

Benchtop high speed refrigerated centrifuge TGL-20M can reach a maximum speed of 21000rpm, it can fit fixed angle head rotors for variable volumes,the max capacity is 4*100ml.

Refrigeratio pluma permittit temperaturae temperationem in processu separationis, quod magni momenti est ad integritatem quorundam exemplorum conservandam. Disposita est accommodare varias rotors et adaptatores fixi-anguli, idoneos faciens ad summam celeritatem centrifugationem voluminum ab 0.2ml usque ad 100ml discurrentium. Consilium compactum reddit id specimen pro laboratorio cum spatio stricto.

Design

● Habitatio metallica, operculum metallicum, et fabricae fabricae chalybeis immaculatae sunt autoclave-biles et renitentes detergentes et disinfection liquidorum.

● Observationes fenestrae in operculo ad celeritatem calibrationis et sonitus mensurae.

Microprocessor imperium cum frequentia conversionem AC motricium coegi

● LCD parametros velocitatis, Timer, RCF, Rotors, Programma (Memoria), Acceleratio & Deceleratio informationes ac Erroris notas exhibe.

Duplex strata obsignatio operculo fabricato ad fabricam fabricam et instrumentum ad diuturnitatem boni obsignandi.

3

user benignos

● CFC refrigerandi liberum, sensorem temperatum intra thalamum, pluma refrigerationis praecellens, temperatura subtilis temperantiae usque ad – 20°C.

● Programmabile et reponendum, usque ad XXX programmata reponit ac directum user accessum praebet cum uno keystroke nisi. Parametrum repositum: iunctura manet in memoria etiam post centrifugationem emissa est.

Acceleratio rates praebet et 10 aggerem bracchium, ut sedimentationem secundariam efficaciter vitet, cum effectu centrifugationis meliore.

Lorem operculo-densis et tenens in rotor run

● Rotors commutabiles facile, speciales rotor iunctio, qui facilem faciunt rotor onerare et exonerare.

● Lorem sollicitudin ante indicatis erroris code et terrorem in screen.

● Sonitus gradu inferiori quam 58 decibel in summa celeritate gyratorii.

● Rotor identitatis automaticae, identificatio rotor coded impedit rotorem super velocitate.

-1

salutem

Salutis et signa Certification: CE

Product Salutis: EN61010-1 and EN 61010-2-020,

Electromagnetic Compatibility: EN 61326-1

● Salus operculi electricae interlock, ianua aperire non potest cum rotor currit et apparatus non currit cum operculo aperto et in codice error apparet.

● Subitis operculo-cincinno emissio cum potentia deficiendi (utilissima in inopinato potentiae interruptione).

● Gas cardo operculi stilla munimenti.

● Praesidia salutis fiunt pro cursu, super calefactione (motor, cubiculo), inaequalitate etc. ut homo salutem machinam conservet.

2

Celeritate range (rpm)0-21000rpm vocabularyTempus range1-99minutes Novifacta
Max Capacity(ml)4* 100mlceleritate accuracy±10r/min
RCF range (xg)0-31061xg vocabularyACC/DEC1-10 rates
Imperium temperatus range-20 ℃ ~ ℃ 40Accuracy temperatus imperium± 1 ℃
Strepitu (dBA)58dB(A)Net pondus (sine rotor)80KGS
potentia copiaAC220V,50HZ,10A, 880WRatio (mm)600x570x380mm (LxWxH)
No.ItemMax. facultatemMax.speedMax.RCFNota
NO.11Angulus rotor12×1.5/2.2ml21000r / min31061xgPP/PC tube
nibhII x 12mlPP/PC tube
nibhII x 12mlPP/PC tube
NO.2imagoAngulus rotorII x 12ml16500r / min19480xgPP/PC tube
nibhII x 12mlPP/PC tube
NO.3imagoAngulus rotorII x 12ml15000r / min21130xgPP/PC tube
nibhII x 12mlPP/PC tube
nibhII x 12mlPP/PC tube
NO.4imagoAngulus rotor24×1.5/2.2ml16000r / min24843xgPP/PC tube
nibhII x 24mlPP/PC tube
nibhII x 24mlPP/PC tube
N0.5imagoAngulus rotor48×1.5/2.2ml14000r / min20379xgPP/PC tube
nibhII x 48mlPP/PC tube
nibhII x 48mlPP/PC tube
NO.6imagoAngulus rotor12×8×0.2ml12000r / min16985xgPCR 8-tubus flammula
NO.77Angulus rotorII x 10ml13000r / min19650xgPP/PC tube
nibhII x 10mlPP/PC tube
nibhII x 10mlPP/PC tube
NO.88Angulus rotorII x 6ml13000r / min18327xgPP/PC tube
nibhII x 6mlPP/PC tube
nibhII x 6mlPP/PC tube
nibh6×3×1.5mlPP/PC tube
NO.99Angulus rotor4 × 10/100ml11000r / min13284xgPP/PC tube
nibhII x 4mlPP/PC tube
nibhII x 4mlPP/PC tube
nibhII x 4mlPP/PC tube
nibhII x 4mlPP/PC tube
nibhII x 4mlPP/PC tube
-3

1.Professio centrifugium opificem, pretium competitive.

2.ISO9001, ISO13485, CE, SFDA Certificatione, omnes machinae qualitatem strictam experiuntur et bonae sarcinae ante translationem subeunt.

3. Longum tempus technicum subsidium ac professionalis servitii in omni stadio producti venditionis, partus et operationis. Nostri quadrigis maxime idonei et periti servitii praebent te singulari gradu subsidii pro tua emptione pro tota vita sua.

4. Etiam solutiones nativus pro clientium specialibus requisitis offerre possumus.

5. Potestas cum efficiente machinarum iunctione per annos experientiae in suis propriis agris adiuta, societas unumquemque productum efficit, quod unitas fabricandi relinquit ad omnia usque ad finem.

QUAESITUM
0
inquisitionis canistro
    Saved consultationi tuae
inanisInquiry