Hot Products
Minimum Volo Benchtop Centrifuge Brushless Motor Safty Lid Lock
| Applications: | Hospitalium, Veterinaria clinica, Labs Cibus, Universitates & Collegia, Pharmaceutical Labs, Cellula culturae Labs, Infantium statio |
| Max.Speed | 4000rpm |
| Max.RCF | 2268xg |
| Max.Capacity | 6* 50ml angulus rotor |
| matched Rotors | Fixum angulum rotors |
| Display | LCD |
| Model Number: | KC40-T |
| Certification: | CE, ISO13485, ISO9001, SFDA |
| Suspendisse | 1 annus warantum pro tota machina, 3 annorum warantum pro compressore et 5 annis warantizatio motoris. Free partes replacement et naves intra warantum. |
- Description
- Video
- Technical Specifications
- Rotors and Accessories
- competitive Italiae Commodum Collegit
The benchtop centrifuge KC40-T is available with numerous fixed-angle rotors. The extensive range of accessories can accommodate tubes from 2 ml to 50 ml. The maximum RCF of more than 2,680 x g is suitable for many application areas in clinical diagnostics, veterinary medicine, pharmaceutics, environmental analysis and industrial production, as well as universities and research facilities.
Design
● Habitatio metallica, operculum metallicum, et 304# cubiculi fabricae ferri incorruptae sunt autoclave-biles et purgationes et disinfection liquidorum repugnantes.
● Rotor ex mixtura aluminii.
● Observationes fenestrae in operculo ad celeritatem calibrationis et sonitus mensurae.
● Imperium microprocessoris cum motore DC sine spazzolis sine cura.
● LCD parametros Celeritatis, Temporis, et RCF ostendit.

user benignos
● Operculo automatario obfirmato et tenendo in rotore currendo.
● Rotores facile permutabiles.
● Lorem sollicitudin ante indicatis erroris code et terrorem in screen.
technologiam mutam patentem. Vox minor quam 55 decibel in summa celeritate gyratorii.

salutem
Produci secundum normas securitatis internationales (eg IEC 61010)
● Salus operculi electricae interlock, ianua aperire non potest cum rotor currit et apparatus non currit cum operculo aperto et in codice error apparet.
● Subitis operculo-cincinno emissio cum potentia deficiendi.
● Gas cardo operculi stilla munimenti.
● Praesidia salutis ad celeritatem excessivam, inaequalitatem, et diagnosim errorum automaticorum etc. fiunt ut salus hominis-machinae confirmetur.

| Celeritate range (rpm) | 0-4000rpm vocabulary | celeritate accuracy | ±10rpm |
| Max Capacity(ml) | 12* 20ml | RCF range (xg) | 0-2680xg vocabulary |
| Strepitu (dBA) | 55dB(A) | Tempus range | 0-99minutes Novifacta |
| Ratio (mm) | 430x320x250mm | Net pondus (sine rotor) | 18KGS |
| potentia copia | AC 220V, 50Hz, 5A, 120W | ||
| No. | rotor | captum | Max.speed | Max.RCF | Nota |
NO.1![]() | Angulus rotor | 24×10/5ml | 4000r / min | 2680xg | PP/PC tube / Vacuum sanguinis collectionem tube |
| nibh | II x 24ml | ||||
| nibh | II x 24ml | ||||
NO.2![]() | Angulus rotor | 6 × 50 ml | 4000r / min | 2680xg | PP/PC tube |
| nibh | 6×15/10ml | ||||
| nibh | 6×5/2ml | ||||
![]() | |||||
1. Centrifugium professionalis fabrica, pretium competitive.
2. ISO9001, ISO13485, CE, SFDA Certificatione, omnes machinae qualitatem strictam experiuntur et bonae sarcinae ante translationem subeunt.
3. Diu terminus technicum auxilium et professio servitii in omni stadio producti venditio, traditio et operation. Nostra summa habilis et peritus servitii quadrigis praebens te singulari gradu subsidii pro tua emptione tota vita sua est.
4. Etiam solutiones nativus pro clientium specialibus requisitis offerre possumus.
5. Powered cum efficiente machinarum iunctione per annos experientiae in suis quisque agris adiuta, societas unumquemque productum efficit, quod unitas fabricandi relinquit ad omnia usque ad finem.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ













